Search results for "Perfusion Imaging"

showing 10 items of 25 documents

Dynamic contrast-enhanced myocardial perfusion imaging using saturation-prepared TrueFISP.

2002

Purpose To develop and test a saturation-recovery TrueFISP (SR-TrueFISP) pulse sequence for first-pass myocardial perfusion imaging. Materials and Methods First-pass magnetic resonance imaging (MRI) of Gd-DTPA (2 mL) kinetics in the heart was performed using an SR-TrueFISP pulse sequence (TR/TE/α = 2.6 msec/1.4 msec/55°) with saturation preparation TD = 30 msec before the TrueFISP readout. Measurements were also performed with a conventional saturation-recovery TurboFLASH (SRTF) pulse sequence for comparison. Results SR-TrueFISP images were of excellent quality and demonstrated contrast agent wash-in more clearly than SRTF images. The signal increase in myocardium was higher in SR-TrueFISP …

AdultGadolinium DTPAMaterials scienceImage qualityContrast MediaImage processingStatistics NonparametricMyocardial perfusion imagingNuclear magnetic resonancePrecontrastCoronary CirculationmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingImage resolutionmedicine.diagnostic_testbusiness.industryPhantoms ImagingMicrocirculationMagnetic resonance imagingPulse sequenceMagnetic Resonance ImagingNuclear medicinebusinessPerfusionJournal of magnetic resonance imaging : JMRI
researchProduct

Comparison of three accelerated pulse sequences for semiquantitative myocardial perfusion imaging using sensitivity encoding incorporating temporal f…

2007

Purpose To investigate the parallel acquisition technique sensitivity encoding incorporating temporal filtering (TSENSE) with three saturation-recovery (SR) prepared pulse sequences (SR turbo fast low-angle shot [SR-TurboFLASH], SR true fast imaging with steady precession [SR-TrueFISP], and SR-prepared segmented echo-planar-imaging [SR-segEPI]) for semiquantitative first-pass myocardial perfusion imaging. Materials and Methods In blood- and tissue-equivalent phantoms the relationship between signal intensity (SI) and contrast-medium concentration was evaluated for the three pulse sequences. In volunteers, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and normalized upslopes (N…

AdultMaleImage qualityContrast MediaImage processingSensitivity and SpecificityMyocardial perfusion imagingHeart RateImage Processing Computer-AssistedImage noiseHumansMedicineRadiology Nuclear Medicine and imagingmedicine.diagnostic_testEcho-Planar ImagingPhantoms ImagingPulse (signal processing)business.industryMyocardiumReproducibility of ResultsLinearityMagnetic resonance imagingMagnetic Resonance ImagingPerfusionLinear rangeFemalebusinessNuclear medicineBiomedical engineeringJournal of Magnetic Resonance Imaging
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

Pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance identifies very early cardiac involvement in systemic scler…

2017

Objective To evaluate occult cardiac involvement in asymptomatic systemic sclerosis (SSc) patients by pharmacological stress, rest perfusion and delayed enhancement cardiac magnetic resonance (CMR), for a very early identification of patients at higher risk of cardiac-related mortality. Methods Sixteen consecutive patients with definite SSc, fulfilling the American College of Rheumatology/European League Against Rheumatism 2013 classification criteria in less than 1 year from the onset of Raynaud's phenomenon, underwent pharmacological stress, rest perfusion and delayed enhancement CMR. At enrollment, no patient showed signs and/or symptoms suggestive for cardiac involvement. No patient sho…

AdultMalemedicine.medical_specialtyAdenosineHeart diseaseHeart DiseasesVasodilator AgentsContrast MediaMagnetic Resonance Imaging CineAsymptomaticCardiac magnetic resonance imaging with pharmacological stress; Myocardial perfusion defect; Systemic sclerosis; Systemic sclerosis heart involvement; Rheumatology030218 nuclear medicine & medical imaging03 medical and health sciencesMyocardial perfusion imagingCoronary circulation0302 clinical medicineRheumatologyPredictive Value of TestsInternal medicineCoronary CirculationCardiac magnetic resonance imaging with pharmacological stressMultidetector Computed TomographymedicineHumans030203 arthritis & rheumatologyScleroderma Systemicmedicine.diagnostic_testbusiness.industryMicrocirculationMyocardial Perfusion Imagingmedicine.diseaseRheumatologymyocardial perfusion defectSettore MED/16 - Reumatologiamedicine.anatomical_structureEarly DiagnosisVentriclecardiac magnetic resonance imaging with pharmacological streAsymptomatic Diseasessystemic sclerosis heart involvementSystemic sclerosisFemaleRadiologymedicine.symptombusinessPerfusionsystemic sclerosiRheumatism
researchProduct

Stable microvascular angina: instrumental evaluation of coronary microvascular dysfunction with coronary angiography and myocardial scintigraphy

2014

Coronary angiographyMyocardial scintigraphymedicine.medical_specialtybusiness.industryCoronary angiographyMicrocirculationMyocardial Perfusion ImagingMicrovascular anginaChest painSettore MED/11 - Malattie Dell'Apparato CardiovascolareMicrocirculationChest painMicrovascular anginaInstrumental evaluationMyocardial scintigraphyInternal medicineCoronary CirculationCardiologyMedicineHumansmedicine.symptomCardiology and Cardiovascular MedicinebusinessRetrospective Studies
researchProduct

Myocardial Perfusion and Fractional Flow Reserve

2013

Myocardial CT perfusion imaging is a rapidly evolving technology that allows assessment of the functional significance of potentially obstructive coronary stenosis. The opportunity for quantification of myocardial perfusion is the greatest potential advantage of CT compared with other perfusion techniques. On the other hand, fractional flow reserve during coronary angiography provides a functional assessment of coronary lesions identified with this modality. Recently, a non-invasive method for estimating fractional flow reserve, based on coronary CT angiography has been introduced. Nevertheless, at present neither CT perfusion nor CT FFR are ready for widespread use in clinical routine.

Coronary angiographymedicine.medical_specialtymedicine.diagnostic_testbusiness.industryCoronary ct angiographyPerfusion scanningCoronary stenosisFractional flow reserveMyocardial perfusion imagingInternal medicineCardiologymedicineFunctional significancebusinessPerfusion
researchProduct

Quantification of Myocardial Blood Flow Using Magnetic Resonance Imaging with Different accelerated Pulse Sequences

2009

The aim of this study was to compare SRTurboFLASH, SR-TrueFISP, and SR-segEPI pulse sequences using a twofold TSENSE-acceleration with regard to their use in quantification of myocardial blood flow (MBF). Six healthy volunteers were examined at 1.5T by first pass myocardial perfusion MRI at rest using all three TSENSE-accelerated pulse sequences. For absolute quantifi-cation of MBF XSIM software with the MMID4 model has been used. MBF analyses revealed significant MBF differences between SRTurboFLASH and SR-segEPI compared to SR-TrueFISP (p<0.005 and p<0.001, respectively). Differences between SRTurboFLASH and SR-segEPI were not statistically significant. The median MBF values for SR-TurboF…

First passMyocardial perfusion imagingNuclear magnetic resonancemedicine.diagnostic_testPulse (signal processing)Image qualityHealthy volunteersmedicineMagnetic resonance imagingBlood flowPerfusionBiomedical engineeringMathematics
researchProduct

Quantification of pulmonary blood flow (PBF): validation of perfusion MRI and nonlinear contrast agent (CA) dose correction with H(2)15O positron emi…

2009

Validation of quantification of pulmonary blood flow (PBF) with dynamic, contrast-enhanced MRI is still missing. A possible reason certainly lies in difficulties based on the nonlinear dependence of signal intensity (SI) from contrast agent (CA) concentration. Both aspects were addressed in this study. Nine healthy pigs were examined by first-pass perfusion MRI using gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) and HO positron emission tomography (PET) imaging. Calculations of hemodynamic parameters were based on a one-compartment model (MR) and a two-compartment model (PET). Simulations showed a significant error when assuming a linear relation between MR SI and CA dose in the …

Gadolinium DTPAPulmonary CirculationCalibration curveSwinemedia_common.quotation_subjectGadoliniumPerfusion ImagingHemodynamicschemistry.chemical_elementContrast MediaSensitivity and SpecificityStandard deviationOxygen RadioisotopesmedicineContrast (vision)AnimalsRadiology Nuclear Medicine and imagingmedia_commonmedicine.diagnostic_testbusiness.industryReproducibility of ResultsWaterMagnetic resonance imagingImage EnhancementchemistryPositron emission tomographyPositron-Emission TomographyRadiopharmaceuticalsNuclear medicinebusinessArtifactsPerfusionMagnetic Resonance AngiographyMagnetic resonance in medicine
researchProduct

Non invasive blood flow measurement in cerebellum detects minimal hepatic encephalopathy earlier than psychometric tests

2013

AIM: To assess whether non invasive blood flow measurement by arterial spin labeling in several brain regions detects minimal hepatic encephalopathy. METHODS: Blood flow (BF) was analyzed by arterial spin labeling (ASL) in different brain areas of 14 controls, 24 cirrhotic patients without and 16 cirrhotic patients with minimal hepatic encephalopathy (MHE). Images were collected using a 3 Tesla MR scanner (Achieva 3T-TX, Philips, Netherlands). Pulsed ASL was performed. Patients showing MHE were detected using the battery Psychometric Hepatic Encephalopathy Score (PHES) consisting of five tests. Different cognitive and motor functions were also assessed: alterations in selective attention we…

Liver CirrhosisMaleCerebellumPathologyPerfusion scanningArterial spin labellingCognitionCerebellumAttentionHepatic encephalopathyCyclic GMPmedicine.diagnostic_testGastroenterologyGeneral MedicineBlood flowMiddle AgedMagnetic Resonance Imagingmedicine.anatomical_structurePredictive value of testsCerebrovascular CirculationFemaleInflammation MediatorsBlood Flow Velocitymedicine.medical_specialtyPsychometricsPerfusion ImagingMinimal hepatic encephalopathymacromolecular substancesMotor ActivityNitric OxideAmmoniaPredictive Value of TestsRetrospective StudymedicineHumansAgedRetrospective Studiesbusiness.industryNon invasiveMagnetic resonance imagingBlood flowmedicine.diseaseEarly DiagnosisRegional Blood FlowHepatic EncephalopathyStroop TestbusinessPsychometric testsBiomarkersNeurological impairment
researchProduct

Prevalence and prognostic impact of nonischemic late gadolinium enhancement in stress cardiac magnetic resonance

2020

Aim To assess the prevalence and prognostic significance of NI-LGE in patients undergoing stress-CMR. Methods Stress-CMR with either dipyridamole or adenosine was performed in 283 patients (228 men, 81%) including perfusion imaging, wall motion evaluation and LGE. Follow-up was completed in all enrolled patients (median time: 1850 days; interquartile range: 1225-2705 days). Composite endpoint included cardiac death, ventricular tachycardia, myocardial infarction, stroke, hospitalization for cardiac cause and coronary revascularization performed beyond 90 days from stress-CMR scans. Results One hundred and twelve patients (40%) had negative LGE (no-LGE), 140 patients (49%) I-LGE and 31 patie…

MaleAdenosineTime FactorsVasodilator AgentsContrast MediaPerfusion scanning030204 cardiovascular system & hematologyVentricular tachycardia0302 clinical medicineRisk FactorsInterquartile rangePrevalence030212 general & internal medicineMyocardial infarctionStrokenonischemic fibrosislate gadolinium enhancement; nonischemic cardiac findings; nonischemic fibrosis; prognosis; stress perfusion cardiac magnetic resonanceDipyridamoleGeneral MedicineMiddle AgedMagnetic Resonance ImagingDipyridamolelate gadolinium enhancementstress perfusion cardiac magnetic resonanceembryonic structurescardiovascular systemCardiologyFemaleCardiology and Cardiovascular MedicinePerfusionmedicine.drugnonischemic cardiac findingsmedicine.medical_specialtyHeart DiseasesPerfusion ImagingRisk Assessment03 medical and health sciencesPredictive Value of TestsInternal medicinemedicineHumanscardiovascular diseasesSurvival analysisAgedRetrospective Studiesbusiness.industryMyocardiummedicine.diseaseFibrosisLate gadolinium enhancement Nonischemic cardiac findings Nonischemic fibrosis Prognosis Stress perfusion cardiac magnetic resonanceprognosisbusinessJournal of Cardiovascular Medicine
researchProduct